FlexSeT is a modular Square D low-voltage switchboard featuring an I-Line distribution stack. FlexSeT is designed to shorten project lead times. Available up to 1600A group mounted or 2000A fixed main breaker. Designed for flexible configuration, assembly, installation and maintenance.

FlexSeT at a glance

Maximum group-mounted main-breaker rating, 80% rated
0 A
Maximum fixed-main breaker rating, 80% rated
0 A
Maximum fault-current rating
0 kAIC
Rated neutral throughout the switchboard
0 %

Ratings and certifications per the Square D FlexSeT sales sheet (998-22386229_GMA-US). Confirm final ratings against the project submittal.

What it is

FlexSeT Switchboards Keep Projects on Schedule

Schneider Electric’s low-voltage switchboard portfolio includes QED-2, RapidSource QED-2 pre-engineered configurations for expedited delivery, and the modular FlexSeT platform. FlexSeT is designed to shorten the ordering and assembly process through simplified configuration and modular construction.

FlexSeT supports digital assembly and documentation workflows. Asset Lifecycle Manager provides digital access to lineup documentation, while digital assembly tools for authorized assemblers support quality assurance and traceability.

Features

FlexSeT Features That Make Installation and Maintenance Easier

Explore the key FlexSeT features and how they help simplify installation, improve access and support ongoing maintenance once the switchboard arrives on site.

Asset Lifecycle Manager

Asset Lifecycle Manager makes lineup documentation digitally accessible so it can be maintained and retrieved throughout the equipment lifecycle.

Visi-Tite Bolts

Visi-Tite bolts provide visual and physical indication that the intended torque level has been achieved during assembly. Inspection and maintenance should follow Schneider Electric’s current instructions.

Bus Bridge

Fast to install at all phases in one movement, and it encloses the bussing structure within a barrier assembly with no exposed bus.

Captive Screws

Always in place and never lost, for faster access to the switchboard. A small thing until you are on a ladder holding a panel.

Swing-out Main

No more manually handling heavy cable to get at the main, which turns an awkward job into a normal maintenance task.

I-Line with Plug-on Neutral

The exclusive I-Line stack for quick and familiar assembly, installation and maintenance, with 100 percent rated neutral throughout the switchboard.

Instrument Compartment

Instrument compartment mounted devices up to 480V, including a maintenance mode switch, 240kA surge protection and a PM5563 meter.

Modular by Design

Adapt to late changes without impacting your project schedule using modular assembly options, and accept connected and digitisation offers as they come.

Specifications

FlexSeT switchboards electrical ratings

Main Breaker Ratings

Available up to 2000A group mounted or a 2500A fixed main breaker, both at 80 percent rated.

System Voltages

600Y/347V, 480Y/277V and 208Y/120V, three phase four wire, 60Hz.

Bus and Fault Rating

Silver plated copper busbar material on all phases and ground, with a maximum fault current rating of 65kAIC.

Instrument Compartment

Instrument compartment mounted devices up to 480V: maintenance mode switch, 240kA surge protection and a PM5563 meter.

How FlexSeT Is Designed to Shorten Project Lead Time

Schneider Electric attributes FlexSeT lead-time reduction to simplified configuration, faster quote-to-order conversion and modular assembly. Actual lead time depends on the approved configuration, order timing and product availability.

See it for yourself

Introducing FlexSeT

Square D walks through what changed in the new generation of low voltage switchboards.

Where FlexSeT Fits

FlexSeT is designed for low-voltage power-distribution applications that benefit from modular construction, I-Line assembly, digital documentation and adaptability to project changes. Final suitability depends on system voltage, amperage, fault-current rating, enclosure and approved project requirements.

Frequently asked

FlexSeT Product Questions

FlexSeT is a modular Square D low-voltage switchboard featuring an I-Line distribution stack. It is available up to 2,000A group-mounted or 2,500A with a fixed-main breaker.

Square D lists it as available up to 2000A group mounted or a 2500A fixed main breaker, both at 80 percent rated. System voltages are 600Y/347V, 480Y/277V and 208Y/120V, three phase four wire 60Hz, with a maximum fault current rating of 65kAIC and NEMA-1 or NEMA-2 enclosures. Always confirm final ratings against the project submittal.

Configuration requires the single-line diagram, load schedule, system voltage, main rating, fault-current rating, enclosure requirements and any required metering or surge-protection options.

Schneider Electric attributes the reduction to simplified configuration, faster quote-to-order conversion and modular assembly options. Actual lead time depends on the final approved configuration, order timing and availability.

Visi-Tite bolts provide visual and physical indication that the intended torque level has been achieved during assembly. They do not replace the inspection and maintenance procedures in Schneider Electric’s current instructions.

Service-entrance suitability depends on the specific configuration, listing, incoming arrangement and approved project submittal. Confirm the required service-entrance rating and markings on the final engineered lineup.

Need FlexSeT switchboards on your next Orlando job?

Start with the single-line diagram, load schedule, system voltage, amperage, fault-current rating and enclosure requirements.

Accessibility
X

Accessibility Widget
We use the UserWay accessibility widget to help make our website more accessible. Look for the accessibility icon on the side of your screen to access tools including:

  • Screen reader support
  • Contrast adjustments
  • Text size scaling
  • Dyslexia-friendly fonts
  • Pause animations
  • Keyboard navigation

We are committed to continuously improving access to our goods and services by individuals with disabilities.
If you are unable to use any aspect of this website because of a disability, please call (407) 422-9841 and we will provide you with prompt personalized assistance.

If you have trouble seeing web pages, the US Social Security Administration offers these tips for optimizing your computer and browser to improve your online experience.

If you are looking for mouse and keyboard alternatives, speech recognition software such as Dragon Naturally Speaking may help you navigate web pages and online services. This software allows the user to move focus around a web page or application screen through voice controls.

If you are deaf or hard of hearing, there are several accessibility features available to you.

Closed Captioning
Closed captioning provides a transcript for the audio track of a video presentation that is synchronized with the video and audio tracks. Captions are generally visually displayed over the video, which benefits people who are deaf and hard of hearing, and anyone who cannot hear the audio due to noisy environments. Most of our website's video content includes automated captions. Learn how to turn captioning on and off in YouTube.

Volume Controls
Your computer, tablet, or mobile device has volume control features. Each video and audio service has its own additional volume controls. Try adjusting both your device's volume controls and your media players' volume controls to optimize your listening experience.


View Full Accessibility Statement

Browse by Page
Search the Website
What are you looking for?
Popular